Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Acquisition speed comparison of microscope software programs
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 755104
Author(s) Biehlmaier, O.; Hehl, J.; Csucs, G.
Author(s) at UniBasel Biehlmaier, Oliver
Year 2011
Title Acquisition speed comparison of microscope software programs
Journal Microscopy Research and Technique
Volume 74
Number 6
Pages / Article-Number 539-45
Abstract Reliable software is a prerequisite for successful operation of a modern wide field fluorescence microscope. When used for live cell imaging, acquisition speed is of particular interest. This is both because biological processes can be highly-dynamic, and to avoid unnecessary photobleaching and phototoxicity of living samples. This article shows that besides the hardware (microscope) components themselves, the acquisition control software is an important influencing factor of speed performance. We tested and compared the speed performance of five different generic applications (Image-Pro Plus, MetaMorph, Micro-Manager, SlideBook, and Volocity) using typical experimental setups involving a single specific state-of-the-art fluorescence microscope configuration. The test measurements included multichannel experiments, z-stacking, burst acquisition, as well as combinations of these measurements with time-lapse acquisitions. The measured data provided values for guiding the testing and analysis of other microscope systems with similar configurations. Despite the identical hardware settings, significant and surprisingly large speed differences were evident among the various software applications. Additionally, no application was identifiable as the fastest in all tests. Our work pinpoints the importance of the control software in determining a system`s ``real`` maximal imaging speed. The study could serve as basis for further tests, eventually influencing the system selection criteria for speed-sensitive applications. Microsc. Res. Tech., 2010. (c) 2010 Wiley-Liss, Inc.
Publisher Wiley
ISSN/ISBN 0741-0581 ; 1097-0029
edoc-URL http://edoc.unibas.ch/45821/
Full Text on edoc No
Digital Object Identifier DOI 10.1002/jemt.20944
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/21604324
ISI-Number WOS:000291539200010
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.348 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
26/04/2024