One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4665168
Author(s) Afshari, Roya; Santini, Francesco; Heule, Rahel; Meyer, Craig H.; Pfeuffer, Josef; Bieri, Oliver
Author(s) at UniBasel Afshari, Roya
Bieri, Oliver
Santini, Francesco
Year 2020
Title One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction
Journal Magnetic Resonance in Medicine
Volume 85
Number 5
Pages / Article-Number 2686-2695
Abstract Purpose : Magnetization transfer ratio (MTR) histograms are widely used for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast but confounding factors should be minimized for high reproducibility. To this end, a one-minute whole brain spiral MTR method with intrinsic B 1 -field correction is introduced. Methods : A spiral multi-slice spoiled gradient echo sequence with adaptable magnetization transfer (MT) saturation pulses (angle b) is proposed. After a low-resolution single-shot spiral readout and a dummy preparation period, high-resolution images are acquired using an interleaved spiral readout. For whole brain MTR imaging, fifty interleaved slices with three different MT contrasts (b = 0°, 350°, 550°) together with an intrinsic B 1 -field map are recorded in 58.5s on a clinical 3T system. From the three contrasts, two sets of MTR images are derived and used for subsequent B 1 correction, assuming a linear dependency on b. For validation, a binary spin bath model is used. Results : For the proposed B 1 -correction scheme, numerical simulations indicate for brain tissue a decrease of about a factor of ten for the B 1 -related bias on MTR. As a result, upon B 1 -correction, MTR differences in gray and white matter become markedly accentuated and the reproducibility of MTR histograms from scan-rescan experiments is improved. Furthermore, B 1 -corrected MTR histograms show a lower variability for age-matched normal appearing brain tissue. Conclusion : From its speed and offering intrinsic B 1 -correction, the proposed method shows excellent prospects for clinical studies that explore MT-effects based on MTR histogram analysis.
Publisher Wiley
ISSN/ISBN 0740-3194 ; 1522-2594
edoc-URL https://edoc.unibas.ch/94380/
Full Text on edoc Restricted
Digital Object Identifier DOI 10.1002/mrm.28618
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/33349950
ISI-Number WOS:000596777900001
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.341 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    