Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Verification-phase tests show low reliability and add little value in determining VO2max in young trained adults
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4621746
Author(s) Wagner, Jonathan; Niemeyer, Max; Infanger, Denis; Hinrichs, Timo; Guerra, Clement; Klenk, Christopher; Königstein, Karsten; Cajochen, Christian; Schmidt-Trucksäss, Arno; Knaier, Raphael
Author(s) at UniBasel Wagner, Jonathan
Hinrichs, Timo
Knaier, Raphael
Year 2021
Title Verification-phase tests show low reliability and add little value in determining VO2max in young trained adults
Journal PLoS ONE
Volume 16
Number 1
Pages / Article-Number e0245306
Mesh terms Adult; Circadian Rhythm, physiology; Exercise; Female; Humans; Male; Oxygen Consumption, physiology; Reproducibility of Results
Abstract This study compared the robustness of a [Formula: see text]-plateau definition and a verification-phase protocol to day-to-day and diurnal variations in determining the true [Formula: see text]. Further, the additional value of a verification-phase was investigated.; Eighteen adults performed six cardiorespiratory fitness tests at six different times of the day (diurnal variation) as well as a seventh test at the same time the sixth test took place (day-to-day variation). A verification-phase was performed immediately after each test, with a stepwise increase in intensity to 50%, 70%, and 105% of the peak power output.; Participants mean [Formula: see text] was 56 ± 8 mL/kg/min. Gwet's AC1 values (95% confidence intervals) for the day-to-day and diurnal variations were 0.64 (0.22, 1.00) and 0.71 (0.42, 0.99) for [Formula: see text]-plateau and for the verification-phase 0.69 (0.31, 1.00) and 0.07 (-0.38, 0.52), respectively. In 66% of the tests, performing the verification-phase added no value, while, in 32% and 2%, it added uncertain value and certain value, respectively, in the determination of [Formula: see text].; Compared to [Formula: see text]-plateau the verification-phase shows lower reliability, increases costs and only adds certain value in 2% of cases.
Publisher Public Library of Science
ISSN/ISBN 1932-6203
edoc-URL https://edoc.unibas.ch/83793/
Full Text on edoc No
Digital Object Identifier DOI 10.1371/journal.pone.0245306
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/33428687
 
   

MCSS v5.8 PRO. 0.393 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
19/04/2024