Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A new processing scheme for ultra-high resolution direct infusion mass spectrometry data
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4525691
Author(s) Zielinski, Arthur T.; Kourtchev, Ivan; Bortolini, Claudio; Fuller, Stephen J.; Giorio, Chiara; Popoola, Olalekan A. M.; Bogialli, Sara; Tapparo, Andrea; Jones, Roderic L.; Kalberer, Markus
Author(s) at UniBasel Kalberer, Markus
Year 2018
Title A new processing scheme for ultra-high resolution direct infusion mass spectrometry data
Journal ATMOSPHERIC ENVIRONMENT
Volume 178
Pages / Article-Number 129-139
Keywords UHRMS; ESI; APPI; Environmental samples; Direct infusion; Orbitrap
Mesh terms Science & TechnologyLife Sciences & BiomedicinePhysical SciencesEnvironmental SciencesMeteorology & Atmospheric SciencesEnvironmental Sciences & EcologyMeteorology & Atmospheric Sciences
Abstract High resolution, high accuracy mass spectrometry is widely used to characterise environmental or biological samples with highly complex composition enabling the identification of chemical composition of often unknown compounds. Despite instrumental advancements, the accurate molecular assignment of compounds acquired in high resolution mass spectra remains time consuming and requires automated algorithms, especially for samples covering a wide mass range and large numbers of compounds. A new processing scheme is introduced implementing filtering methods based on element assignment, instrumental error, and blank subtraction. Optional post-processing incorporates common ion selection across replicate measurements and shoulder ion removal. The scheme allows both positive and negative direct infusion electrospray ionisation (ESI) and atmospheric pressure photoionisation (APPI) acquisition with the same programs. An example application to atmospheric organic aerosol samples using an Orbitrap mass spectrometer is reported for both ionisation techniques resulting in final spectra with 0.8% and 8.4% of the peaks retained from the raw spectra for APPI positive and ESI negative acquisition, respectively.
Publisher PERGAMON-ELSEVIER SCIENCE LTD
ISSN/ISBN 1352-2310
edoc-URL https://edoc.unibas.ch/74522/
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.atmosenv.2018.01.034
ISI-Number 000428104200014
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.356 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    