Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Pilot Ex Vivo Study of Laser-Induced Breakdown Spectroscopy to Detect Bone Dehydration: An Approach for Irrigation Feedback in Laserosteotomy
ConferencePaper (Artikel, die in Tagungsbänden erschienen sind)
 
ID 4515249
Author(s) Abbasi, Hamed; Sugiarto, Irena; Rauter, Georg; Guzman, Raphael; Cattin, Philippe; Zam, Azhar
Author(s) at UniBasel Sugiarto, Irena
Rauter, Georg
Guzman, Raphael
Cattin, Philippe Claude
Zam, Azhar
Abbasi, Hamed
Year 2018
Title Pilot Ex Vivo Study of Laser-Induced Breakdown Spectroscopy to Detect Bone Dehydration: An Approach for Irrigation Feedback in Laserosteotomy
Book title (Conference Proceedings) 2018 International Conference on Electrical Engineering and Computer Science (ICEECS)
Place of Conference Bali, Indonesia
Year of Conference 2018
Publisher ICEECS
Keywords LIBS, plasma spectroscopy, bone dehydration, minimally invasive surgery, laserosteotome
Abstract A successful laserosteotome should cut the bone without inducing thermal damage to the surrounding tissue, otherwise the healing process will be prolonged. To avoid such thermal damage, laserosteotomes typically employ an irrigation system with a pre-defined flow rate of cooling water. If this pre-defined flow rate is insufficient, for any reason, the laser beam will induce thermal damage by first dehydrating and then carbonizing the tissue. On the other hand, a too high water flow rate will result in lower ablation rates since the laser beam first needs to ablate the extra water before cutting bone, especially with lasers that water has a high absorption peak in their wavelengths, like Er:YAG and CO2. While a feedback mechanism detecting carbonization has been demonstrated in literature already, it would be desirable to detect possible dehydration at an earlier stage (underirrigation) where the tissue damage is still negligible. This pilot study evaluates the applicability of laser-induced breakdown spectroscopy (LIBS) to detect bone dehydration already at its onset. The results confirmed a good accuracy of over 89 % (cross-validated) in classifying normal and dehydrated bone.
URL https://iceecs2018.org/wp-content/uploads/2019/10/paper_050.pdf
edoc-URL https://edoc.unibas.ch/72285/
Full Text on edoc Available
Digital Object Identifier DOI 10.5281/zenodo.3514693
 
   

MCSS v5.8 PRO. 0.407 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    