Evaluation of the Clinitek®, a point-of-care urinalysis system for the measurement of clinically significant urinary metabolites and detection of haematuria in Schistosoma haematobium infected children in southern Côte d'Ivoire
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4508702
Author(s) Panic, Gordana; Barda, Beatrice; Kovač, Jana; Coulibaly, Jean T.; Keiser, Jennifer
Author(s) at UniBasel Panic, Gordana
Barda, Beatrice
Kovac, Jana
Coulibaly, Jean
Keiser, Jennifer
Year 2019
Title Evaluation of the Clinitek®, a point-of-care urinalysis system for the measurement of clinically significant urinary metabolites and detection of haematuria in Schistosoma haematobium infected children in southern Côte d'Ivoire
Journal Parasites and vectors
Volume 12
Number 1
Pages / Article-Number 298
Abstract Urinary schistosomiasis, caused by Schistosoma haematobium, remains a significant public health problem worldwide, despite years of efforts to control it. Haematuria is one of the notable indirect indicators of S. haematobium infection and is commonly assessed along with other routine screens using a urinary dipstick test. A portable "field friendly" electronic analyser would offer an automated and thus more objective read-out compared to visual-read dipstick methods.; Within the framework of a Phase 2 praziquantel dose finding study in preschool- and school-aged children infected with S. haematobium, in southern Côte d'Ivoire, we compared a visual-read of the urine dipstick strips (Multistix PRO, Siemens Healthcare Diagnostics) to an automated reader (CLINITEK Status+ analysertm Siemens Healthcare Diagnostics). Urine samples were collected from 148 pre-school aged and 152 school-aged children for urinalysis. Values were compared using a linear weighted kappa statistic and Bland-Altman analysis.; A very good correlation between the two methods for nitrites and haematuria was observed (κ coefficient of 0.88 and 0.82, respectively), while a good correlation was observed for leukocytes (κ coefficient of 0.63) A moderate to fair correlation was calculated (κ coefficient ≤ 0.6) for all other parameters. When the results were stratified according to infection intensity, the agreements were stronger from the high infection intensity sample measurements, for most of the parameters.; Our results demonstrate the device's utility in detecting haematuria and nitrites but underline the need for further development of this tool in order to improve its performance in the field.
Publisher BioMedCentral
ISSN/ISBN 1756-3305
edoc-URL https://edoc.unibas.ch/71139/
Full Text on edoc Available
Digital Object Identifier DOI 10.1186/s13071-019-3555-z
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/31196145
ISI-Number WOS:000471630000003
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.360 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
03/05/2024