Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4499932
Author(s) Knaier, Raphael; Höchsmann, Christoph; Infanger, Denis; Hinrichs, Timo; Schmidt-Trucksäss, Arno
Author(s) at UniBasel Hinrichs, Timo
Knaier, Raphael
Infanger, Denis
Höchsmann, Christoph
Schmidt-Trucksäss, Arno
Year 2019
Title Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X
Journal BMC public health
Volume 19
Number 1
Pages / Article-Number 244
Mesh terms Accelerometry, instrumentation; Adult; Algorithms; Exercise; Female; Hip; Humans; Male; Monitoring, Ambulatory, instrumentation; Time Factors; Wearable Electronic Devices, statistics & numerical data; Wrist; Young Adult
Abstract Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting.; Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings.; Mean wear time was over 1420 min per day for both devices on all days. Lin's concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were - 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were - 17.5 ± 10% in Troiano and - 0.8 ± 4.6% in Choi.; Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level.
Publisher BMC
ISSN/ISBN 1471-2458
URL https://bmcpublichealth.biomedcentral.com/track/pdf/10.1186/s12889-019-6568-9
edoc-URL https://edoc.unibas.ch/69778/
Full Text on edoc No
Digital Object Identifier DOI 10.1186/s12889-019-6568-9
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/30819148
ISI-Number WOS:000460041100012
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.338 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    