Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Miniaturized Sample Preparation for Transmission Electron Microscopy
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4485175
Author(s) Schmidli, Claudio; Rima, Luca; Arnold, Stefan A.; Stohler, Thomas; Syntychaki, Anastasia; Bieri, Andrej; Albiez, Stefan; Goldie, Kenneth N.; Chami, Mohamed; Stahlberg, Henning; Braun, Thomas
Author(s) at UniBasel Stahlberg, Henning
Chami, Mohamed
Goldie, Kenneth
Braun, Thomas
Year 2018
Title Miniaturized Sample Preparation for Transmission Electron Microscopy
Journal Journal of Visualized Experiments
Number 137
Pages / Article-Number e57310
Mesh terms Humans; Microfluidics, methods; Microscopy, Electron, Transmission, methods; Proteomics, methods; Single-Cell Analysis, methods
Abstract Due to recent technological progress, cryo-electron microscopy (cryo-EM) is rapidly becoming a standard method for the structural analysis of protein complexes to atomic resolution. However, protein isolation techniques and sample preparation methods for EM remain a bottleneck. A relatively small number (100,000 to a few million) of individual protein particles need to be imaged for the high-resolution analysis of proteins by the single particle EM approach, making miniaturized sample handling techniques and microfluidic principles feasible. A miniaturized, paper-blotting-free EM grid preparation method for sample pre-conditioning, EM grid priming and post processing that only consumes nanoliter-volumes of sample is presented. The method uses a dispensing system with sub-nanoliter precision to control liquid uptake and EM grid priming, a platform to control the grid temperature thereby determining the relative humidity above the EM grid, and a pick-and-plunge-mechanism for sample vitrification. For cryo-EM, an EM grid is placed on the temperature-controlled stage and the sample is aspirated into a capillary. The capillary tip is positioned in proximity to the grid surface, the grid is loaded with the sample and excess is re-aspirated into the microcapillary. Subsequently, the sample film is stabilized and slightly thinned by controlled water evaporation regulated by the offset of the platform temperature relative to the dew-point. At a given point the pick-and-plunge mechanism is triggered, rapidly transferring the primed EM grid into liquid ethane for sample vitrification. Alternatively, sample-conditioning methods are available to prepare nanoliter-sized sample volumes for negative stain (NS) EM. The methodologies greatly reduce sample consumption and avoid approaches potentially harmful to proteins, such as the filter paper blotting used in conventional methods. Furthermore, the minuscule amount of sample required allows novel experimental strategies, such as fast sample conditioning, combination with single-cell lysis for "visual proteomics," or "lossless" total sample preparation for quantitative analysis of complex samples.
Publisher JoVE
ISSN/ISBN 1940-087X
URL https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6126565/
edoc-URL https://edoc.unibas.ch/65447/
Full Text on edoc No
Digital Object Identifier DOI 10.3791/57310
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/30102271
ISI-Number WOS:000444836300016
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.352 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
01/05/2024