Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Osteoarthritis alters the patellar bones subchondral trabecular architecture
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4406209
Author(s) Hoechel, Sebastian; Deyhle, Hans; Toranelli, Mireille; Muller-Gerbl, Magdalena
Author(s) at UniBasel Müller-Gerbl, Magdalena
Year 2016
Title Osteoarthritis alters the patellar bones subchondral trabecular architecture
Journal Journal of Orthopaedic Research
Volume 35
Number 9
Pages / Article-Number 1982-1989
Keywords 3D micro-CT; human patella; osteoarthritic trabecular changes; subchondral bone plate mineralization
Mesh terms Calcification, Physiologic; Female; Humans; Male; Middle Aged; Osteoarthritis, Knee, pathology; Patella, pathology; X-Ray Microtomography
Abstract Following the principles of "morphology reveals biomechanics," the cartilage-osseous interface and the trabecular network show defined adaptation in response to physiological loading. In the case of a compromised relationship, the ability to support the load diminishes and the onset of osteoarthritis (OA) may arise. To describe and quantify the changes within the subchondral bone plate (SBP) and trabecular architecture, 10 human OA patellae were investigated by CT and micro-CT. The results are presented in comparison to a previously published dataset of 10 non-OA patellae which were evaluated in the same manner. The analyzed OA samples showed no distinctive mineralization pattern in regards to the physiological biomechanics, but a highly irregular disseminated distribution. In addition, no regularity in bone distribution and architecture across the trabecular network was found. We observed a decrease of material as the bone volume and trabecular thickness/number were significantly reduced. In comparison to non-OA samples, greatest differences for all parameters were found within the first mm of trabecular bone. The differences decreased toward the fifth mm in a logarithmic manner. The interpretation of the logarithmic relation leads to the conclusion that the main impact of OA on bony structures is located beneath the SBP and lessens with depth. In addition to the clear difference in material with approximately 12% less bone volume in the first mm in OA patellae, the architectural arrangement is more rod-like and isotropic, accounting for an architectural decrease in stability and support. (c) 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Publisher WILEY
ISSN/ISBN 0736-0266 ; 1554-527X
URL https://www.ncbi.nlm.nih.gov/pubmed/27879001
edoc-URL https://edoc.unibas.ch/62371/
Full Text on edoc No
Digital Object Identifier DOI 10.1002/jor.23490
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/27879001
ISI-Number WOS:000410205600018
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.325 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
18/04/2024