Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A combined application of tunable diode laser absorption spectroscopy and isothermal micro-calorimetry for calorespirometric analysis
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 4211104
Author(s) Brueckner, David; Solokhina, Anna; Krähenbühl, Stephan; Braissant, Olivier
Author(s) at UniBasel Krähenbühl, Stephan
Year 2017
Title A combined application of tunable diode laser absorption spectroscopy and isothermal micro-calorimetry for calorespirometric analysis
Journal Journal of Microbiological Methods
Volume 139
Pages / Article-Number 210-214
Abstract Calorespirometry is the simultaneous analysis of the rate of heat emission (Rq), O2 consumption (RO2) and CO2 production (RCO2) by living systems such as tissues or organism cultures. The analysis provides useful knowledge about thermodynamic parameters relevant for e.g. biotechnology where parameter based yield maximization (fermentation) is relevant. The determination of metabolism related heat emission is easy and normally done by a calorimeter. However, measuring the amount of consumed O2 and produced CO2 can be more challenging, as additional preparation or instrumentation might be needed. Therefore, tunable diode laser absorption spectroscopy (TDLAS) was investigated as an alternative approach for respirometric analysis in order to facilitate the data collection procedure. The method determines by a spectroscopic laser non-invasively CO2 and O2 gas concentration changes in the respective vial headspaces. The gathered growth data from Pseudomonas aeruginosa cultured in two different scarce media was used to compute respiratory quotient (RQ) and calorespirometric ratios (CRCO2 [Rq/RCO2], CRO2 [Rq/RO2]). A comparison of the computed (experimental) values (for RQ, CRCO2 and CRO2) with values reported in the literature confirmed the appropriateness of TDLAS in calorespirometric studies. Thus, it could be demonstrated that TDLAS is a well-performing and convenient way to evaluate non-invasively respiratory rates during calorespirometric studies. Therefore, the technique is definitively worth to be investigated further for its potential use in research and in diverse productive environments.
Publisher Elsevier
ISSN/ISBN 0167-7012 ; 1872-8359
edoc-URL https://edoc.unibas.ch/59263/
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.mimet.2017.06.012
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/28627416
ISI-Number WOS:000405154900037
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.352 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
18/04/2024