Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 3724693
Author(s) Roth, Ralf; Donath, Lars; Kurz, Eduard; Zahner, Lukas; Faude, Oliver
Author(s) at UniBasel Zahner, Lukas
Year 2017
Title Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
Journal Physical Therapy in Sport
Volume 24
Pages / Article-Number 26-31
Abstract The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000).; Test-retest-protocol on five separate days.; Fifteen healthy sport students (8 female and 7 male) aged 21 to 26.; PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks.; For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% < CoV < 9.4%; 0.15 < SEM < 0.23) and isokinetic mode (60°/s: 3.7% < CoV < 8.6%; 0.08 < SEM < 0.24; 150°/s: 6.9% < CoV < 12.4%; 0.10 < SEM < 0.31). In contrast, reliability between familiarization day and day 1 was lower (6.6% < CoV < 26.2%; 0.10 < SEM < 0.65).; Trunk strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied.
Publisher Elsevier
ISSN/ISBN 1466-853X ; 1873-1600
edoc-URL http://edoc.unibas.ch/54159/
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.ptsp.2016.11.005
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/27964928
ISI-Number WOS:000397833400005
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.375 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
26/04/2024