Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Determination of the new HIV-protease inhibitor atazanavir by liquid chromatography after solid-phase extraction
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 3704480
Author(s) Colombo, S.; Guignard, N.; Marzolini, C.; Telenti, A.; Biollaz, J.; Decosterd, L. A.
Author(s) at UniBasel Marzolini, Catia
Year 2004
Title Determination of the new HIV-protease inhibitor atazanavir by liquid chromatography after solid-phase extraction
Journal Journal of Chromatography B
Volume 810
Number 1
Pages / Article-Number 25-34
Mesh terms Atazanavir Sulfate; Buffers; Calibration; Chromatography, High Pressure Liquid; Freezing; HIV Protease Inhibitors, blood; Humans; Indicators and Reagents; Oligopeptides, blood; Pyridines, blood; Reference Standards; Reproducibility of Results; Solutions; Specimen Handling; Spectrophotometry, Ultraviolet
Abstract An HPLC method previously described for the simultaneous assay of amprenavir, ritonavir, indinavir, saquinavir, nelfinavir and efavirenz is proposed here for the simultaneous analysis of the new HIV protease inhibitor atazanavir (ATV) in human plasma, by off-line solid-phase extraction (SPE) followed by HPLC coupled with UV-diode array detection. After viral inactivation by heat (60 degrees C for 60 min), plasma (600 microl) with clozapine (internal standard) is diluted 1 + 1 with phosphate buffer pH 7 and subjected to a SPE on a C18 cartridge. Matrix components are eliminated with 2 x 500 microl of a solution of 0.1% H(3)PO(4) neutralised with NaOH to pH 7. ATV is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 100 microl MeOH/H(2)O 50/50. A 40 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. ATV is analysed by UV detection at 201 nm using a gradient elution program with solvents constituted of MeCN and phosphate buffer adjusted to pH 5.14. The mobile phase also contains 0.02% sodium heptanesulfonate, enabling an excellent separation of ATV from the other HIV protease inhibitors (PIs) amprenavir, indinavir, saquinavir, ritonavir, lopinavir, nelfinavir and the non-nucleoside reverse transcriptase inhibitors (NNRTIs) efavirenz and nevirapine. The calibration curves are linear up to 10 microg/ml, with a lower limit of quantification of 0.2 microg/ml. The mean absolute recovery of ATV is 96.4 +/- 3.2%. The method is precise with mean inter-day CVs within 1.1-6.1%, and accurate (range of inter-day deviations +0.3 to +2.3%). The method has been validated and is currently applied to the monitoring of ATV in HIV patients.
Publisher Elsevier
ISSN/ISBN 1570-0232 ; 1873-376X
edoc-URL https://edoc.unibas.ch/69538/
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.jchromb.2004.07.008
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/15358304
ISI-Number WOS:000224010000004
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.355 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
09/05/2024