Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A compact, efficient, and lightweight laser head for CARLO: integration, performance, and benefits
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 3289151
Author(s) Deibel, Waldemar; Schneider, Adrian; Augello, Marcello; Bruno, Alfredo E.; Juergens, Philipp; Cattin, Philippe
Author(s) at UniBasel Cattin, Philippe Claude
Year 2015
Title A compact, efficient, and lightweight laser head for CARLO: integration, performance, and benefits
Journal Proceedings of SPIE
Volume 9579
Pages / Article-Number 957905
Abstract Ever since the first functional lasers were built about 50 years ago, researchers and doctors dream of a medical use for such systems. Today's technology is finally advanced enough to realize these ambitions in a variety of medical fields. There are well-established laser based systems in ophthalmology, dental applications, treatment of kidney stones, and many more. Using lasers presents more than just an alternative to conventional methods for osteotomies. It offers less tissue damage, faster healing times, comparable intervention duration and in consequence improves postoperative treatment of patients. However, there are a few factors that limit routine applications. These technical drawbacks include missing depth control and safe guiding of the laser beam. This paper presents the engineering and integration of a miniaturized laser head for a computer assisted and robot-guided laser osteotome (CARLO (R)), which can overcome the mentioned drawbacks. The CARLO (R) device ensures a safe and precise guidance of the laser beam. Such guidance also enables new opportunities and methods, e.g. free geometrical functional cuts, which have the potential to revolutionize bone surgery. The laser head is optimized for beam shaping, target conditioning, working distance, compactness and the integration of all other parts needed, e.g. CCD-cameras for monitoring and referencing, a visible laser for cut simulation, etc. The beam coming out of the laser system is conditioned in shape, energy properties and working distance with an optical arrangement to achieve the desired cutting performance. Here also parameters like optical losses, operating mode, optics materials and long-term stability have are taken into account.
Publisher SPIE
ISSN/ISBN 1996-756X
edoc-URL http://edoc.unibas.ch/39643/
Full Text on edoc No
Digital Object Identifier DOI 10.1117/12.2187992
ISI-Number WOS:000365757600004
Document type (ISI) Proceedings Paper
 
   

MCSS v5.8 PRO. 0.335 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
19/04/2024