Automated dual capillary electrophoresis system with hydrodynamic injeciton for the concurrent determination of cations and anions
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 2827213
Author(s) Thi Thanh Thuy Pham; Thanh Duc Mai; Thanh Dam Nguyen; Saiz, Jorge; Hung Viet Pham; Hauser, Peter C.
Author(s) at UniBasel Hauser, Peter C.
Year 2014
Title Automated dual capillary electrophoresis system with hydrodynamic injeciton for the concurrent determination of cations and anions
Journal Analytica chimica acta
Volume 841
Pages / Article-Number 77-83
Keywords Dual-capillary electrophoresis, Capacitively coupled contactless conductivity detection (C4D), Simultaneous separations, Cations, Anions
Abstract The capillary electrophoresis instrument developed for the concurrent determination of cations and anions features two separate capillaries and individual detectors to allow independent optimization for each group of ions. The capillaries are joined in a common injector block. The sample is drawn into the injector with a small membrane pump and automated simultaneous injection into both capillaries is achieved by pressurization of the fluid with compressed air. Flushing of the injector and of the capillaries with the background electrolyte is also carried out automatically by the same means. The buffer consisted of 12 mM histidine and 2 mM 18-crown-6 adjusted to pH 4 with acetic acid and was suitable for the contactless conductivity detection employed. The system was optimized for the determination of cationic NH4+ and anionic NO3 and NO2, and linear calibration curves from about 20 mM up to about 1.5 mM were obtained for these ions. In a test run over 8 h, the reproducibility for the peak areas was within +/- 7%. For demonstration, the instrument was successfully applied to the concurrent monitoring of the concentrations of the three ions during the biological removal of ammonium from contaminated groundwater in a sequencing batch reactor, where NO3- and NO2- are formed as intermediate products. (C) 2014 Elsevier B. V. All rights reserved.