2dx_automator: Implementation of a semiautomatic high-throughput high-resolution cryo-electron crystallography pipeline
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 2590626
Author(s) Scherer, Sebastian; Kowal, Julia; Chami, Mohamed; Dandey, Venkata; Arheit, Marcel; Ringler, Philippe; Stahlberg, Henning
Author(s) at UniBasel Stahlberg, Henning
Chami, Mohamed
Year 2014
Title 2dx_automator: Implementation of a semiautomatic high-throughput high-resolution cryo-electron crystallography pipeline
Journal Journal of Structural Biology
Volume 186
Number 2
Pages / Article-Number 302-307
Keywords 2dx, Image processing automation, Cryo-EM, Direct electron detector, High-throughput electron microscopy, Membrane proteins
Mesh terms Cryoelectron Microscopy, instrumentation, methods; Crystallography, methods; High-Throughput Screening Assays, methods; Humans; Imaging, Three-Dimensional; Models, Molecular; Potassium Channels, chemistry, ultrastructure; Software; User-Computer Interface
Abstract The introduction of direct electron detectors (DED) to cryo-electron microscopy has tremendously increased the signal-to-noise ratio (SNR) and quality of the recorded images. We discuss the optimal use of DEDs for cryo-electron crystallography, introduce a new automatic image processing pipeline, and demonstrate the vast improvement in the resolution achieved by the use of both together, especially for highly tilted samples. The new processing pipeline (now included in the software package 2dx) exploits the high SNR and frame readout frequency of DEDs to automatically correct for beam-induced sample movement, and reliably processes individual crystal images without human interaction as data are being acquired. A new graphical user interface (GUI) condenses all information required for quality assessment in one window, allowing the imaging conditions to be verified and adjusted during the data collection session. With this new pipeline an automatically generated unit cell projection map of each recorded 2D crystal is available less than 5min after the image was recorded. The entire processing procedure yielded a three-dimensional reconstruction of the 2D-crystallized ion-channel membrane protein MloK1 with a much-improved resolution of 5Å in-plane and 7Å in the z-direction, within 2days of data acquisition and simultaneous processing. The results obtained are superior to those delivered by conventional photographic film-based methodology of the same sample, and demonstrate the importance of drift-correction.
Publisher Elsevier
ISSN/ISBN 1047-8477 ; 1095-8657
edoc-URL http://edoc.unibas.ch/dok/A6263209
Full Text on edoc Available
Digital Object Identifier DOI 10.1016/j.jsb.2014.03.016
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/24680783
ISI-Number WOS:000335705700011
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.337 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    