Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Evaluation of the CALIOPE air quality forecasting system for epidemiological research : the example of NO2 in the province of Girona (Spain)
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 2355815
Author(s) Aguilera, I.; Basagaña, X.; Pay, M. T.; Agis, D.; Bouso, L.; Foraster, M.; Rivera, M.; Baldasano, J. M.; Künzli, N.
Author(s) at UniBasel Künzli, Nino
Year 2013
Title Evaluation of the CALIOPE air quality forecasting system for epidemiological research : the example of NO2 in the province of Girona (Spain)
Journal Atmospheric environment
Volume 72
Pages / Article-Number 134-141
Keywords Air quality modeling, Model evaluation, NO2, Passive sampling
Abstract Background: Air quality models are being increasingly used to estimate long-term individual exposures to air pollution in epidemiological studies. Most of them have been evaluated against measurements from a limited number of monitoring stations, which may not properly reflect the exposure characteristics of the study population.Methods: We evaluated the performance of the high-resolution CALIOPE air quality forecasting system over a large sample of passive measurements of NO2 conducted at 635 home outdoor locations of the Girona province (Spain) during several 4-week sampling campaigns over one year (July 2007-June 2008). Sampling sites were superposed over the 4 km x 4 km CALIOPE grid, and average NO2 modeled concentrations were derived for all measurements conducted during the same sampling campaign at all the sampling sites located within the same grid cell. In addition, the ratio between measured and modeled concentrations for the whole study period at one fixed monitoring station was used to post-process the modeled values at the home outdoor locations.Results: The correlation between measured and modeled concentrations for the entire study area (which includes urban settings, middle-size towns, and rural areas) was 0.78. Modeled concentrations were underestimated in the whole study area. After correcting the modeled concentrations by the measured to modeled ratio at the fixed station (r = 0.25), they were very similar to the measured concentrations (27.7 mu g m(-3) and 29.3 mu g m(-3), respectively). However, the performance of the modeling system depends on the type of subarea and is affected by the sub-grid emission sources.Conclusions: The evaluation over the heterogenous Girona province showed that CALIOPE is able to reproduce the spatial variability of 4-week NO2 concentrations at the small regional level. CALIOPE output data is a valuable tool to complement study-specific air pollution measurements by incorporating regional spatial variability as well as short- and long-term temporal variability of background pollution in epidemiological research. (C) 2013 Elsevier Ltd. All rights reserved.
Publisher Elsevier Science
ISSN/ISBN 1352-2310
edoc-URL http://edoc.unibas.ch/dok/A6223272
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.atmosenv.2013.02.035
ISI-Number WOS:000318262000017
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.327 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
17/06/2024