Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A simple microextraction and preconcentration approach based on a mixed matrix membrane
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 2310246
Author(s) Kamaruzaman, Sazlinda; Hauser, Peter C; Sanagi, Mohd Marsin; Ibrahim, Wan Aini Wan; Endud, Salasiah; See, Hong Heng
Author(s) at UniBasel Hauser, Peter C.
Year 2013
Title A simple microextraction and preconcentration approach based on a mixed matrix membrane
Journal Analytica chimica acta
Volume 783
Pages / Article-Number 24-30
Keywords Sample preparation, Mixed matrix membrane, Microextraction, Non-steroidal anti-inflammatory drugs
Abstract

A simple adsorption/desorption procedure using a mixed matrix membrane (MMM) as extraction medium is demonstrated as a new miniaturized sample pretreatment and preconcentration technique. Reversed-phase particles namely polymeric bonded octadecyl (C-18) was incorporated through dispersion in a cellulose triacetate (CIA) polymer matrix to form a C-18-MMM. Non-steroidal anti-inflammatory drugs (NSAIDs) namely diclofenac, mefenamic acid and ibuprofen present in the environmental water samples were selected as targeted model analytes. The extraction setup is simple by dipping a small piece of C-18-MMM (7 mm X 7 mm) in a stirred 10 mL sample solution for analyte adsorption process. The entrapped analyte within the membrane was then desorbed into 100 mu L of methanol by ultrasonication prior to high performance liquid chromatography (HPLC) analysis. Each membrane was discarded after single use to avoid any analyte carry-over effect. Several important parameters, such as effect of sample pH, salting-out effect, sample volume, extraction time, desorption solvent and desorption time were comprehensively optimized. The C-18-MMM demonstrated high affinity for NSAIDs spiked in tap and river water with relative recoveries ranging from 92 to 100% and good reproducibility with relative standard deviations between 1.1 and 5.5% (n = 9). The overall results obtained were found comparable against conventional solid phase extraction (SPE) using cartridge packed with identical C-18 adsorbent. (C) 2013 Elsevier B.V. All rights reserved.

Publisher Elsevier
ISSN/ISBN 0003-2670
edoc-URL http://edoc.unibas.ch/dok/A6212111
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.aca.2013.04.042
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/23726096
ISI-Number WOS:000320427000003
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.348 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
19/04/2024