Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Changes in gait patterns and muscle activity following total hip arthroplasty: A six-month follow-up
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 2116656
Author(s) Horstmann, Thomas; Listringhaus, Rico; Haase, Götz-Bernhard; Grau, Stefan; Mündermann, Annegret
Author(s) at UniBasel Mündermann, Annegret
Year 2013
Title Changes in gait patterns and muscle activity following total hip arthroplasty: A six-month follow-up
Journal Clinical biomechanics
Volume 28
Number 7
Pages / Article-Number 762-9
Mesh terms Arthroplasty, Replacement, Hip; Biomechanical Phenomena; Electromyography; Exercise Test; Female; Follow-Up Studies; Gait, physiology; Hip Joint, physiopathology; Humans; Knee Joint, physiopathology; Male; Middle Aged; Muscle, Skeletal, physiopathology; Postoperative Period; Range of Motion, Articular, physiology; Reference Values; Reproducibility of Results; Walking
Abstract Appropriate gait function is an important determinant of the outcome of total hip arthroplasty and relies on appropriate joint motion and muscle activity. The purpose of this study was to test the hypothesis that 6-month postoperative dynamic joint range of motion, time-distance measures and muscle activity in the operated limb in patients undergoing total hip arthroplasty differ from preoperative levels and are more similar to those observed postoperatively in the contralateral limb and in healthy subjects.; Basic time-distance gait measurements, knee and hip kinematics and electromyographic activity from eight hip muscles were obtained preoperatively and 6months postoperatively in 52 patients undergoing total hip arthroplasty and in 24 age-matched healthy subjects during treadmill walking.; Postoperative dynamic hip range of motion for the operated limb (confidence interval differences [-3.9°; -2.3°]) and postoperative knee range of motion for both limbs (operated: [-8.4°; -5.6°]; contralateral: [-8.1°; -5.3°]) in patients with total hip arthroplasty were significantly lower than values for the control subjects (P<0.001). Postoperative gait in patients with total hip arthroplasty was more symmetric than preoperative gait. Preoperative and postoperative electromyographic intensities were higher in patients with total hip arthroplasty than values for the control subjects (P<0.001), and patients had different EMG patterns compared to the control group.; Pre- and postoperative differences not only in hip but also in knee kinematics emphasize the importance of evaluating the dynamic outcome of total hip arthroplasty by assessing joint motion of all lower extremity joints in both legs.
Publisher Elsevier
ISSN/ISBN 0268-0033 ; 1879-1271
edoc-URL http://edoc.unibas.ch/58490/
Full Text on edoc No
Digital Object Identifier DOI 10.1016/j.clinbiomech.2013.07.001
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/23906936
ISI-Number WOS:000325588600008
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.379 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
30/04/2024