Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1764998
Author(s) Coulibaly, Jean T; N'Gbesso, Yves K; Knopp, Stefanie; N'Guessan, Nicaise A; Silué, Kigbafori D; van Dam, Govert J; N'Goran, Eliézer K; Utzinger, Jürg
Author(s) at UniBasel Utzinger, Jürg
Year 2013
Title Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment
Journal PLoS neglected tropical diseases
Volume 7
Number 3
Pages / Article-Number e2109
Abstract

The Kato-Katz technique is widely used for the diagnosis of Schistosoma mansoni, but shows low sensitivity in light-intensity infections. We assessed the accuracy of a commercially available point-of-care circulating cathodic antigen (POC-CCA) cassette test for the diagnosis of S. mansoni in preschool-aged children before and after praziquantel administration.; A 3-week longitudinal survey with a treatment intervention was conducted in Azaguié, south Côte d'Ivoire. Overall, 242 preschoolers (age range: 2 months to 5.5 years) submitted two stool and two urine samples before praziquantel administration, and 86 individuals were followed-up posttreatment. Stool samples were examined with duplicate Kato-Katz thick smears for S. mansoni. Urine samples were subjected to POC-CCA cassette test for S. mansoni, and a filtration method for S. haematobium diagnosis.; Before treatment, the prevalence of S. mansoni, as determined by quadruplicate Kato-Katz, single CCA considering 'trace' as negative (t-), and single CCA with 'trace' as positive (t+), was 23.1%, 34.3% and 64.5%, respectively. Using the combined results (i.e., four Kato-Katz and duplicate CCA(t-)) as diagnostic 'gold' standard, the sensitivity of a single Kato-Katz, a single CCA(t-) or CCA(t+) was 28.3%, 69.7% and 89.1%, respectively. Three weeks posttreatment, the sensitivity of a single Kato-Katz, single CCA(t-) and CCA(t+) was 4.0%, 80.0% and 84.0%, respectively. The intensity of the POC-CCA test band reaction was correlated with S. mansoni egg burden (odds ratio = 1.2, p = 0.04). CONCLUSIONSSIGNIFICANCE: A single POC-CCA cassette test appears to be more sensitive than multiple Kato-Katz thick smears for the diagnosis of S. mansoni in preschool-aged children before and after praziquantel administration. The POC-CCA cassette test can be recommended for the rapid identification of S. mansoni infections before treatment. Additional studies are warranted to determine the usefulness of POC-CCA for assessing drug efficacy and monitoring the impact of control interventions.

Publisher Public Library of Science
ISSN/ISBN 1935-2727
edoc-URL http://edoc.unibas.ch/dok/A6124535
Full Text on edoc No
Digital Object Identifier DOI 10.1371/journal.pntd.0002109
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/23556011
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.345 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
24/04/2024