Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Nanoscale topographic and biomechanical studies of the human internal limiting membrane
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1370656
Author(s) Henrich, Paul B.; Monnier, Christophe A.; Halfter, Willi; Haritoglou, Christos; Strauss, Rupert W.; Lim, Roderick Y. H.; Loparic, Marko
Author(s) at UniBasel Lim, Roderick
Year 2012
Title Nanoscale topographic and biomechanical studies of the human internal limiting membrane
Journal Investigative ophthalmology & visual science
Volume 53
Number 6
Pages / Article-Number 2561-70
Abstract The purpose of this article was to create a nanometer scale topographic and biomechanical profile of the human internal limiting membrane (ILM) under native conditions. METHODS: ILMs from the posterior pole of postmortem human eyes were prepared as flat mounts and investigated by atomic force microscopy (AFM) under physiological conditions. Structural analysis was complemented by transmission electron microscopy. RESULTS: Average thickness of the fully hydrated, native ILMs was 3488 ± 460 nm. Thickness variations from 100 nm to 4326 nm characterized the fovea, which displayed a craterlike morphology. Outside the fovea, thickness distribution was uniform. Although mean ILM thicknesses were similar, standard deviation was higher on the retinal than on the vitreal side, indicating greater roughness. Average ILM stiffness was more than fivefold higher on the retinal than on the vitreal side (227 vs. 44 kPa). CONCLUSIONS: A detailed topographical and nanomechanical profile of native human ILM was generated using AFM. Thickness values were significantly higher than in previous studies because of the preservation of native conditions. Both thickness and stiffness showed marked variations around the fovea but were relatively uniform outside the foveal area. Interestingly, the foveal ILM displayed a craterlike morphological appearance with four distinct layers separated by comparatively steep thickness increments. ILM stiffness was considerably higher on the retinal than on the vitreal side. AFM opens new possibilities for investigating native basement membranes under physiological and pathological conditions. Transmission electron microscopy revealed higher extracellular matrix protein density on the retinal than on the vitreal side.
ISSN/ISBN 0146-0404
edoc-URL http://edoc.unibas.ch/dok/A6031569
Full Text on edoc Available
Digital Object Identifier DOI 10.1167/iovs.11-8502
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/22410559
ISI-Number MEDLINE:22410559
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.354 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
02/05/2024