Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1196636
Author(s) Hirschmann, Michael T.; Iranpour, Farhad; Konala, Praveen; Kerner, Anna; Rasch, Helmut; Cobb, Justin P.; Friederich, Niklaus F.
Author(s) at UniBasel Friederich, Niklaus F.
Year 2010
Title A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography
Journal Knee surgery, sports traumatology, arthroscopy
Volume 18
Number 7
Pages / Article-Number 939-944
Keywords Knee, SPECT/CT, Replacement, Painful total knee arthroplasty, Localization scheme
Abstract SPECT/CT is a promising diagnostic modality in patients with painful total knee arthroplasty (TKA). The purpose of this study is to introduce a novel standardized SPECT/CT algorithm and evaluate its clinical application and reliability. A novel SPECT/CT localization scheme consisting of 9 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. It was piloted in 18 consecutive patients with post TKA pain. The tracer activity on SPECT/CT was recorded using a color-coded scale (0-10). The inter- and intra-observer reliability was assessed for localization and tracer activity. The prosthetic component position was assessed in the CT images after 3D reconstruction using standardized frames of reference. The median inter- and intra-observer differences and ranges of the measured angles were calculated along with the ICC values for inter- and intra-observer reliability. The localization scheme showed very high inter- and intra-observer reliabilities for all regions. The measurement of component position was highly reliable in all cases with sufficient visibility of anatomical landmarks. The median inter-observer difference between alignment measurements for tibial and femoral components was less than 3 degrees (range 0 degrees -6 degrees ). The median intra-observer variability for these was less than 2 degrees (range 0 degrees -5 degrees ). The SPECT/CT algorithm presented is both reliable and useful in the management of patients with painful TKA. It combines biomechanical and metabolic data (tracer localization) providing an extra dimension to the understanding of this difficult condition. The clinical value of SPECT/CT in patients with unexplained pain following TKA should be further investigated.
Publisher Springer
ISSN/ISBN 0942-2056
edoc-URL http://edoc.unibas.ch/dok/A6006801
Full Text on edoc No
Digital Object Identifier DOI 10.1007/s00167-010-1070-z
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/20148324
ISI-Number WOS:000278931500017
Document type (ISI) Article
 
   

MCSS v5.8 PRO. 0.341 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    