Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
A comparison of acoustic cardiography and echocardiography for optimizing pacemaker settings in cardiac resynchronization therapy
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1196535
Author(s) Zuber, Michel; Toggweiler, Stefan; Quinn-Tate, Lori; Brown, Lei; Amkieh, Ali; Erne, Paul
Author(s) at UniBasel Zuber, Michel
Erne, Paul
Year 2008
Title A comparison of acoustic cardiography and echocardiography for optimizing pacemaker settings in cardiac resynchronization therapy
Journal Pacing and clinical electrophysiology
Volume 31
Number 7
Pages / Article-Number 802-11
Keywords acoustic cardiography, echocardiography, Doppler, biventricular pacing, CRT
Abstract BACKGROUND: Cardiac resynchronization therapy (CRT) is useful in managing patients with refractory heart failure. To increase efficacy, pacemaker settings are optimized, with Doppler echocardiography being the preferred method. Recently, acoustic cardiography, an automated method that records, analyzes, and displays simultaneous ECG and heart sound data, has been developed. In this study, the suitability of acoustic cardiography as an alternative to Doppler echocardiography in CRT optimization is evaluated. METHODS: We studied 43 CRT patients undergoing optimization. Using Doppler echocardiography, we determined the optimal atrioventricular (AV) delay with a transmitral flow assessment. For optimization of the interventricular (VV) delay, we used the left ventricular outflow tract velocity time integral (VTI). For acoustic cardiography, we used the electromechanical activation time (EMAT, the interval from QRS onset to the S1). Reproducibility of echocardiography and acoustic cardiography was determined by programming 10 different delay settings twice in random order. RESULTS: All 43 subjects underwent AV optimization, and 14 had CRT devices allowing VV optimization. While the intraobserver variability of EMAT and Doppler echocardiography parameter was similar (9.9% vs 8.5%), the reproducibility of EMAT was the highest (r = 0.91) and VTI was the lowest (r = 0.35). The correlation between the optimal AV delays determined by EMAT versus transmitral flow assessment was 0.86 (P < 0.001). The correlation between the optimal VV delays determined by EMAT versus VTI was 0.58 (P < 0.05), perhaps due to the poor reproducibility of the VTI. CONCLUSION: For CRT optimization, acoustic cardiography provides results similar to echocardiography but with improved reproducibility and ease of use.
Publisher Blackwell Futura Publishing
ISSN/ISBN 0147-8389
edoc-URL http://edoc.unibas.ch/dok/A6006701
Full Text on edoc No
Digital Object Identifier DOI 10.1111/j.1540-8159.2008.01094.x
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/18684276
ISI-Number WOS:000257705900003
Document type (ISI) Journal Article, Randomized Controlled Trial
 
   

MCSS v5.8 PRO. 0.325 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    