Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Intra-operative myocardial ischaemia cannot be detected by analysis of transmitral inflow patterns in patients undergoing off-pump coronary surgery
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1196485
Author(s) Wang, J; Seeberger, M D; Skarvan, K; Michaux, I; Bernet, F; Arsenic, R; Buser, P; Filipovic, M
Author(s) at UniBasel Seeberger-Stucky, Manfred
Buser, Peter
Filipovic, Miodrag
Year 2008
Title Intra-operative myocardial ischaemia cannot be detected by analysis of transmitral inflow patterns in patients undergoing off-pump coronary surgery
Journal EJA : European journal of anaesthesiology
Volume 25
Number 1
Pages / Article-Number 1-7
Keywords cardiopulmonary bypass, cardiac surgical procedures, myocardial ischaemia, echocardiography doppler
Abstract SummaryBackground and objectiveTransmitral inflow patterns have been used for detection of myocardial ischaemia. However, its diagnostic value has not been tested in anaesthetized and mechanically ventilated patients undergoing coronary artery bypass graft surgery. METHODS: Transmitral inflow patterns were studied by transoesophageal Doppler echocardiography in 43 patients undergoing coronary artery bypass graft surgery without cardiopulmonary bypass after opening of the sternum (baseline) and during grafting of the left anterior descending artery. Peak early (E) and peak late (A) transmitral velocities and their ratio (E/A) were recorded. Myocardial ischaemia was defined by standard criteria using two-dimensional echocardiography and seven-lead electrocardiogram. RESULTS: Thirty-one patients (64 +/- 8 yr, 9 women) fulfilled the predefined inclusion criteria for analysis. During distal revascularization, 16 patients showed myocardial ischaemia and 15 did not. The use of vasoactive drugs, haemodynamic findings and transmitral inflow patterns were similar in both groups at baseline and during grafting. In the ischaemic group, E was 67.1 +/- 13.9 cm s-1 at baseline and 69.5 +/- 23.2 cm s-1 during grafting, and the E/A ratios were 1.3 +/- 0.3 and 1.4 +/- 0.9, respectively. In the non-ischaemic group, E was 64.0 +/- 17.1 cm s-1 at baseline and 60.9 +/- 14.8 cm s-1 during grafting, and the E/A ratios were 1.4 +/- 0.7 and 1.2 +/- 0.3, respectively. CONCLUSIONS: Analysis of Doppler findings of transmitral inflow patterns did not allow for detection of myocardial ischaemia during surgical revascularization of the myocardium.
Publisher Blackwell
ISSN/ISBN 0265-0215
edoc-URL http://edoc.unibas.ch/dok/A6006652
Full Text on edoc No
Digital Object Identifier DOI 10.1017/S0265021507000737
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/17594738
ISI-Number WOS:000252682000001
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.361 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
30/04/2024