Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Evaluating the microstructure of human brain tissues using synchrotron radiation-based micro computed tomography
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1196050
Author(s) Schulz, Georg; Morel, Anne; Imholz, Martha S.; Deyhle, Hans; Weitkamp, Timm; Zanette, Irene; Pfeiffer, Franz; David, Christian; Mueller-Gerbl, Magdalena; Mueller, Bert
Author(s) at UniBasel Müller, Bert
Müller-Gerbl, Magdalena
Year 2010
Title Evaluating the microstructure of human brain tissues using synchrotron radiation-based micro computed tomography
Journal Proceedings of SPIE
Volume 7804
Pages / Article-Number 7804F1-8
Keywords X-ray phase contrast, X-ray grating interferometry, X-ray Talbot interferometry, human brain tissue, human thalamus, histology, stereotactic brain atlas
Abstract Minimally invasive deep brain neurosurgical interventions require a profound knowledge of the morphology of the human brain. Generic brain atlases are based on histology including multiple preparation steps during the sectioning and staining. In order to correct the distortions induced in the anisotropic, inhomogeneous soft matter and therefore improve the accuracy of brain atlases, a non-destructive 3D imaging technique with the required spatial and density resolution is of great significance. Micro computed tomography provides true micrometer resolution. The application to post mortem human brain, however, is questionable because the differences of the components concerning X-ray absorption are weak. Therefore, magnetic resonance tomography has become the method of choice for three-dimensional imaging of human brain. Because the spatial resolution of this method is limited, an alternative has to be found for the three-dimensional imaging of cellular microstructures within the brain. Therefore, the present study relies on the synchrotron radiation-based micro computed tomography in the recently developed grating-based phase contrast mode. Using data acquired at the beamline ID 19 (ESRF, Grenoble, France) we demonstrate that grating-based tomography yields premium images of human thalamus, which can be used for the correction of histological distortions by 3D non-rigid registration.
Publisher SPIE
ISSN/ISBN 0277-786X
edoc-URL http://edoc.unibas.ch/dok/A6006228
Full Text on edoc No
Digital Object Identifier DOI 10.1117/12.859273
ISI-Number WOS:000287816200013
Document type (ISI) Proceedings Paper
 
   

MCSS v5.8 PRO. 0.362 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
28/04/2024