Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Präoperative Genauigkeit von kraniofazialen, in selektiver Lasersinterung-Technik gefertigten 3-D-Modellen, im Vergleich zum primären CT-Datensatz
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1195629
Author(s) Kaim, A H; Kirsch, E C; Alder, P; Bucher, P; Hammer, B
Author(s) at UniBasel Kirsch, Eberhard
Year 2009
Title Präoperative Genauigkeit von kraniofazialen, in selektiver Lasersinterung-Technik gefertigten 3-D-Modellen, im Vergleich zum primären CT-Datensatz
Journal RÖFO : vereinigt mit Aktuelle Radiologie : Fortschritte auf dem Gebiete der Röntgenstrahlen und der bildgebenden Verfahren : Organ der Deutschen Röntgengesellschaft ... [et al.]
Volume 181
Number 7
Pages / Article-Number 644-51
Keywords face, head/neck, CT, dysplasias, technical aspects, CT spiral
Abstract PURPOSE: To evaluate the accuracy of craniofacial 3D models produced in the standardized selective laser sintering (SLS) technique from multislice computed tomography (MSCT) data sets in comparison with patient data and to investigate the effect of potential causes of inaccuracies. MATERIALS AND METHODS: 19 models were considered and examined by MSCT. The patient CT data used for 3D modeling was analyzed and compared to the 3D model data. 15 anatomical landmarks were defined and 20 distances were digitally measured. The digital measurements of both CT data sets were compared to manually measured distances of the SLS model. RESULTS: There was not a statistically significant difference (p < 0.05) between the measurements of the distances concerning all three groups (patient CT data, model CT data, manual measurement of the model). The mean values of the differences were between 0.5455 and -0.3214 mm. CONCLUSION: We found a high accuracy of SLS 3D models, which is due to a high precision in the modeling process and to the small voxel size of patient CT data achieved by MSCT. Anatomical landmarks in patient and model CT data sets and on the 3D model were able to be accurately reproduced, which is important for preoperative planning.
Publisher Thieme
ISSN/ISBN 0340-1618
edoc-URL http://edoc.unibas.ch/dok/A6005811
Full Text on edoc No
Digital Object Identifier DOI 10.1055/s-0028-1109204
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/19253203
ISI-Number WOS:000268678600003
Document type (ISI) Journal Article
Additional Information Note: Englischer Titel: Preoperative accuracy of selective laser sintering (SLS) in craniofacial 3D modeling: comparison with patient CT data
 
   

MCSS v5.8 PRO. 0.354 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
02/05/2024