Data Entry: Please note that the research database will be replaced by UNIverse by the end of October 2023. Please enter your data into the system https://universe-intern.unibas.ch. Thanks

Login for users with Unibas email account...

Login for registered users without Unibas email account...

 
Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography
JournalArticle (Originalarbeit in einer wissenschaftlichen Zeitschrift)
 
ID 1192875
Author(s) Saur, Stefan C.; Alkadhi, Hatem; Stolzmann, Paul; Baumüller, Stephan; Leschka, Sebastian; Scheffel, Hans; Desbiolles, Lotus; Fuchs, Thomas J.; Székely, Gábor; Cattin, Philippe C.
Author(s) at UniBasel Cattin, Philippe Claude
Year 2010
Title Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography
Journal European radiology
Volume 20
Number 7
Pages / Article-Number 1599-606
Keywords Coronary plaque, Observer variability, Evaluation time, Reader experience, Computed tomography coronary angiography
Mesh terms Aged; Aged, 80 and over; Coronary Angiography, methods; Coronary Stenosis, diagnostic imaging; Female; Humans; Male; Middle Aged; Observer Variation; Reproducibility of Results; Retrospective Studies; Tomography, X-Ray Computed, methods
Abstract To assess the effect of reader experience on variability, evaluation time and accuracy in the detection of coronary artery plaques with computed tomography coronary angiography (CTCA). Three independent, blinded readers with three different experience levels twice labelled 50 retrospectively electrocardiography (ECG)-gated contrast-enhanced dual-source CTCA data sets (15 female, age 67.3 +/- 10.4 years, range 46-86 years) indicating the presence or absence of coronary plaques. The evaluation times for the readings were recorded. Intra- and interobserver variability expressed as kappa statistics and sensitivity, specificity, and negative and positive predictive values were calculated for plaque detection, with a consensus reading of the three readers taken as the standard of reference. A bootstrap method was applied in the statistical analysis to account for clustering. Significant correlations were found between reader experience and, respectively, evaluation times (r = -0.59, p < 0.05) and intraobserver variability (r = 0.73, p < 0.05). The evaluation time significantly differed among the readers (p < 0.05). The observer variability for plaque detection, compared with the consensus, varied between kappa = 0.582 and kappa = 0.802. Variability of plaque detection was significantly smaller (p < 0.05) and more accurate (p < 0.05) for the most experienced reader. Reader experience significantly correlated with observer variability, evaluation time and accuracy of coronary plaque detection at CTCA.
Publisher Springer
ISSN/ISBN 0938-7994
edoc-URL http://edoc.unibas.ch/dok/A6003123
Full Text on edoc No
Digital Object Identifier DOI 10.1007/s00330-009-1709-7
PubMed ID http://www.ncbi.nlm.nih.gov/pubmed/20119728
Document type (ISI) Journal Article
 
   

MCSS v5.8 PRO. 0.351 sec, queries - 0.000 sec ©Universität Basel  |  Impressum   |    
19/04/2024